General specifications |
|
Dimensions excl. antenna: |
55 mm by 147 mm by 90 mm |
Weight, battery activated: |
approximately 220 g |
Battery |
water -activated |
Voltage |
19 V |
Transmitter frequencies |
403 MHz |
Windfinding alternatives |
none |
Meteorological sensors |
|
PTU sensors are individually factory calibrated. |
|
Pressure |
BAROCAP® Capacitive aneroid |
Measuring range |
1060 hPa to 3hPa (mb) |
Resolution |
0.1 hPa |
Accuracy |
|
Reproducibility1): |
0.5 hPa |
Repeatability of calibration2): |
0.5 hPa |
Temperature |
THERMOCAP® Capacitive bead |
Measuring range |
+60 °C to - 90 °C |
Resolution |
0.1 °C |
Accuracy: |
|
Reproducibility1): |
0.2 °C up to 50 hPa, 0.3 °C for 50-15 hPa, 0.4°C above
15 hPa level |
Repeatability of calibration2): |
0.2 °C |
Lag: |
< 2.5 s (6 m/s flow at 1000 hPa) |
Humidity |
HUMICAP® Thin film capacitor |
Measuring range: |
0 to 100 % RH |
Resolution: |
1 % RH |
Lag: |
1 s (6 m/s flow at 1000 hPa, +20 °C) |
Accuracy: |
|
Reproducibility1): |
<3 %RH |
Repeatability of calibration2): |
2 %RH |